General Specifications
|
|
|
ELECTRICAL |
|
| Primary Operating Voltage: | 120 VAC, 60 Hz |
| Transformer: | UL listed, Class II, plug-in, 16 VAC, 1.25 A (supplied) |
| Back-Up Battery: | Recommended battery is 12V, 1.2 amp-hour; Linear part number 100104 (order separately) |
| Standby Current Drain: | 120 mA |
| Alarm Current: | 190 mA |
| Backup Operation: | 30 hours minimum |
|
RADIO RECEIVER |
|
| Type: | Diversity, dual superheterodyne |
| Operating Frequency | 315 MHz |
| Transmitter Capacity: |
16 DX or DXS devices |
| RF Programming Method: |
Linear quick-learn |
| Compatible RF Formats: | Linear DX, DXS |
|
CONSOLE |
|
| Radio Zones: | 16 supervised |
| Relay Output: | Form "A" normally open common alarm contact |
| Contact Rating: | 1 amp @ 12 VDC |
| Control Switches: | HELP with Braille, Home with Braille "H", CANCEL with Braille "C" |
| Indicators: | LED type labeled Power, Sending, Status, and Home |
| Connectors: | RJ-31X in and out telephone jacks; relay output terminals, external speaker terminals, external microphone terminals |
| Programming Method: |
Via RA-2400 remote access software |
| Silent Alarm Feature: |
Software programmable per channel |
| Pulse/Tone Dialing: | Software or console programmable |
| Audible Output: | Integral siren, built-in digital voice synthesizor |
| Operating Temperature: | 32° to 120° F (0° to 49° C) |
| Regulatory: | FCC, DOC, UL 1637 |
|
COMMUNICATOR |
|
| Dialing: | DTMF or pulse dialing; pulse speed (10 PPS, 60% break, 40% make) |
| Ringer Equivalence: | 0.4 B |
| Reporting Formats: | 4 x 2 or Ademco Contact ID |
|
Telephone Numbers: |
Primary, secondary, and supervisory |
| Reports: | Full transmitter reports, console reports, general system reports, and inactivity |
|
PHYSICAL CONSOLE |
|
| Dimensions: | 5.25 in L x 9 in W x 4.75 in H (133 x 228 x 120 mm) |
| Weight: | 2.75 lbs. (1.25 kg) |
The PERS-3600 is a feature-rich 24-hour personal emergency reporting system.